					nipom
				
				
				
				 	
						OAO					
					
					
				
				
									
												 
				
								
				
				
				
				
			
			
						
		Low voltage electrical switchboard NKU Freecon
			
				Electricity - electronics- electrotechnical > Energy: production and distribution > Switchgear			
                
				Electricity - electronics- electrotechnical > Energy: production and distribution > Switchgear
				
					
				
			
                
            
            
        Designation
                                                        Low Voltage Electrical Switchboards “NKU” are designed to receive and distribute electric power (0.69 kV, 50  (60) Hz 
three-phase alternative current) among consumers.  
Application
It functions as:
- General switchboards and sub- switchboards, Automatic Transfer Switch (ATS) panels 
- Aggregate panels of electro-technology installations control stations  
- LV Switchgears of Packaged Transformer substations 
- Utilities Switchboards for Electric Generating Stations, etc.
Functional Capabilities
- Electric installations power supply protection-ATS arrangement from electric power system (max. 2 lead-ins) and emergency power supply sources, in particular, from electric power system (max. 2 lead-ins) and diesel run power plan (max. 2 lead-ins)
- Control of power supply system parameters and status  
- Local, remote and automatic control of power consumers  
- Reception of control signals and signals generation of consumers status via wire and digital communication channels (Modbus, Profibus)
Construction Merits
“Freecon” Low Voltage Electrical Switchboard is a freely configurable system based on “F4” in-house /  “NIPON” OJSC  / 
form factor —  (for 6,300 A current, max.) and based on “SIVACON S8” licensed unified form factor —  (for 7,000 A current, 
max.) and “Logstrup” —  (for 8,500 A currents, max.). 
Low Voltage Electrical Switchboards are connected to Distribution Networks:
- By cables from below and top 
- By buses  / bus ducts from top, laterally 
Consumers are connected to Low Voltage Electrical Switchboards:
- By cables from below and top 
- By buses  / bus ducts from top 
Modifications:
- CT — single-side  / double side maintenance sections with fixed equipment 
- CM — single-side  / double side maintenance sections with retractable  /  removable modules
Additional Options
- Link with High-Level Automatic Process Control Systems 
- Digital controller for Relay Protection and Automatic Equipment and Automatic Transfer Switch (ATS) 
- Modbus, Profibus Communications Protocols 
- Electric power metering devices with digital data communication to Utility Metering System 
- ATS based on microprocessor relay protection units and Programmable Logic Controllers (PLC) 
- Microprocessor units for electric motors protection  
- Electric equipment status control, event log keeping, data display on a Central Processing Module
| Parameter name | Parameter values | Unit of measure | 
|---|---|---|
| 
							Equipment seismic load resistance as per MSK64 scale
							 | 
																									9
									 
											
												
											
											x
												
											
											x
												
											
										 | 
								
									grade								
								 
										
										
										 x 
										
										 x 
										
									 | 
| 
							Grounding system type
							 | 
																									TN-C, TN-C-S, TN-S
									 
											
												
											
											x
												
											
											x
												
											
										 | 
										
										
										 x 
										
										 x 
										
									 | 
| 
							Rated permissible short time current of bus bars, Icw
							 | 
																									100
									 
											
												
											
											x
												
											
											x
												
											
										 | 
								
									kA								
								 
										
										
										 x 
										
										 x 
										
									 | 
| 
							Rated shock current of bus bars, Ipk
							 | 
																									200
									 
											
												
											
											x
												
											
											x
												
											
										 | 
								
									kA								
								 
										
										
										 x 
										
										 x 
										
									 | 
| 
							Rated Switchboard current
							 | 
																									6300
									 
											
												
											
											x
												
											
											x
												
											
										 | 
								
									A								
								 
										
										
										 x 
										
										 x 
										
									 | 
| 
							Rated voltage
							 | 
																									690
									 
											
												
											
											x
												
											
											x
												
											
										 | 
								
									V								
								 
										
										
										 x 
										
										 x 
										
									 | 
                                distribute electric power (0.69 kV, 50 (60) Hz  three-phase alternative current) among consumers
                            
                        
                                            
                                Low voltage electrical switchboard NKU Freecon,Low voltage electrical switchboard,Low voltage,electrical switchboard,NKU Freecon,Freecon
                            
                                                                    * Indicates required field
        
                
        
        
    
 
						